BNMFK - SURETAP, 17M241A

  • MSDS: BNMFK
  • Manufacturer: KEYSTONE LUBRICANTS
  • Product Name: SURETAP, 17M241A
  • National Stock Number: 9150-00N027868
Product Identification

Product ID:SURETAP, 17M241A
MSDS Date:10/22/1991
FSC:9150
NIIN:00N027868
MSDS Number: BNMFK

Responsible Party
KEYSTONE LUBRICANTS
5 NORTH STILES ST
LINDEN, NJ 07036
US

Emergency Phone: 908-862-2500;800-424-9300(CHEMTREC)

Info Phone: 908-862-2500

Preparer: DAVE TOWNSEND

Cage: KEYST

Contractor
KEYSTONE LUBRICANTS
LINDEN, NJ 07036 US

Telephone: 201-862-2500

Cage: KEYST

Ingredients

POLYALKYLENE GLYCOL; (POLYALKYLENE GLYCOL MIXTURE)


REMOVED FROM SKIN BY WATERLESS HAND CLEANERS

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:HLTH STUDIES HAVE SHOWN THAT MANY
PETRO HYDROCARBONS & SYNTHETIC LUBRICANTS POSE POTENTIAL HUMAN HLTH
RISKS WHICH VARY FROM PERSON TO PERSON. AS A PRECAUTION, EXPOSURE
TO LIQUIDS, VAPORS, MISTS/FUMES SHOULD BE MINIMIZED. PRLNG/RPTD
SKIN CONT W/PROD TENDS TO REMOVE SKIN OILS POSSIBLY LEADING TO
IRRIT & (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:DERM; HOWEVER, BASED ON HUMAN EXPER &
AVAIL TOXICOLOGICAL DATA, THIS PRODUCT IS JUDGED TO BE NEITHER
CORROSIVE NOR AN IRRITANT BY OSHA CRITERIA. PRODUCT CONTACTING EYE
MAY CAUSE IRRIT. PRODUC T HAS LOW ORDER OF ACUTE ORAL & DERMAL
TOXICITY.
Medical Cond Aggravated by Exposure:UNKNOWN.

First Aid

First Aid:EYE:FLUSH W/CLEAR WATER FOR AT LEAST 15 MINUTES/UNTIL
IRRITATION SUBSIDES. IF IRRIT PERSISTS, CALL MD. SKIN:REMOVE CONTAM
CLTHG & WASH THORO W/SOAP & WATER. INGEST:CALL MD IMMEDIATELY.
INHAL:REMOVE TO FRESH AIR. SUPPORT BREATHING (GIVE O*2/ARTF RESP)
.

Fire Fighting

Extinguishing Media:FOAM, WATER SPRAY (FOG), DRY CHEM, CO*2 &
VAPORIZING LIQ TYPE EXTING AGENTS MAY ALL BE SUITABLE FOR EXTING
FIRES(SUPDAT)
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA & FULL PROT
EQUIP . PLAN FIRE PROT & RESPONSE STRATEGY THRU CONSULTATION
W/LOCAL FIRE PROT AUTH/APPROP SPECIALISTS.

Accidental Release

Spill Release Procedures:KEEP PROD OUT OF SEWERS & WATERCOURSES BY
DIKING/IMPOUNDING. ABSORB W/SAND/INERT MATL. SWEEP/SCOOP UP &
REMOVE. PVNT SPREAD OF SPILL. ADVISE AUTHS IF PROD HAS ENTERED/MAY
ENTER SEWERS, WATERCOURSES/EX TENSIVE LAND AREAS. ASSURE CONFORMITY
W/LOC REGS.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:KEEP CONTAINERS CLOSED WHEN NOT IN
USE. DO NOT HANDLE NEAR HEAT, SPARKS, FLAME/STRONG OXIDANTS.
Other Precautions:DO NOT MIX W/NITRITES OR PRODUCTS WHICH CONTAIN
NITRITES. MINIMIZE BREATHING VAPOR, MIST OR FUMES. AVOID PROLONGED
OR REPEATED CONTACT W/SKIN.

Exposure Controls

Respiratory Protection:USE ONLY NIOSH/MSHA APPROVED RESPIRATORS.
NORMALLY NOT NEEDED AT AMBIENT TEMPERATURES.
Ventilation:USE LOCAL EXHAUST TO CAPTURE VAPOR, MIST OR FUMES, IF
NECESSARY. ALWAYS MAINTAIN BELOW PEL.
Protective Gloves:CHEMICAL-RESISTANT GLOVES.
Eye Protection:CHEM WORK GOGG/FULL LENGTH FCSHLD.
Other Protective Equipment:USE CHEM-RESISTANT APRON/OTHER IMPERVIOUS
CLTHG, IF NEEDED, TO AVOID CONTAM REG CLTHG WHICH COULD RESULT IN
(SUPDAT)
Work Hygienic Practices:REMOVE CONTAM CLTHG; LAUNDER/DRY-CLEAN BEFORE
REUSE. REMOVE CONTAM SHOES & THORO CLEAN BEFORE REUSE. CLEANSE
(SUPDAT)
Supplemental Safety and Health
EXTING MEDIA:INVOLVING THIS TYPE PROD, DEPENDING ON SIZE/POTNTL OF FIRE
& CIRCUMSTANCES RELATED TO SITUATION. MATLS TO AVOID:MIX W/NITRITES
DUE TO POSS FORM OF NITROSAMINES. OTHER PROT EQUIP:PRLNG/RPT D SKIN
CONT. HYGIENE PRACT:SKIN THORO AFT CONT, BEFORE BREAKS & MEALS, & @
END OF WORK PERIOD. PROD IS READILY (ING 2)

Chemical Properties

HCC:V6
Boiling Pt:B.P. Text:WIDE RANGE
Spec Gravity:>0.1 (H*2O=1)
Evaporation Rate & Reference:>1.0 (N-BUTYL ACETATE=1)
Solubility in Water:SOLUBLE
Appearance and Odor:PALE YELLOW LIQUID, SLIGHT CHEMICAL ODOR.
Percent Volatiles by Volume:85

Stability

Stability Indicator/Materials to Avoid:YES
AVOID CONT W/STRONG OXIDANTS SUCH AS LIQ CHLORINE, CONC O*2, SODIUM
HYPOCHLORITE/CALCIUM HYPOCHLORITE. DO NOT (SUPDAT)
Stability Condition to Avoid:OPEN FLAMES.
Hazardous Decomposition Products:FUMES, SMOKE, CO & OTHER DECOMPOSITION
PRODUCTS, IN CASE OF INCOMPLETE COMBUSTION.

Disposal

Waste Disposal Methods:CONSULT FEDERAL, STATE OR LOCAL AUTHORITIES FOR
PROPER DISP PROCEDURES. ASSURE CONFORMITY W/APPLIC DISP
REGULATIONS. DISPOSE OF ABSORBED MATL AT APPROVED WASTE SITE OR
FACILITY.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.